熟女无套高潮内谢视频韩国,女人荫蒂全部过潮喷,老熟妇仑乱视频一区二,蜜芽忘忧草三区老狼大豆

您好,歡迎來到歐亞貿(mào)易網(wǎng)!請 |免費注冊

產(chǎn)品展廳本站服務(wù)收藏該商鋪

CHANGSHA LANGSHUO TECHNOLOGY CO LTD

免費會員
手機逛
CHANGSHA LANGSHUO TECHNOLOGY CO LTD
當(dāng)前位置:CHANGSHA LANGSHUO TECHNOLOGY CO LTD>>Alloy XFR Analyzer,Rohs Spectrometer>> R-450 RoHS detector

R-450 RoHS detector

產(chǎn)品二維碼
參  考  價:面議
具體成交價以合同協(xié)議為準(zhǔn)
  • 產(chǎn)品型號:
  • 品牌:
  • 產(chǎn)品類別:元素分析儀器
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時間:2025-07-15 16:33:47
  • 瀏覽次數(shù):4

聯(lián)系我時,請告知來自 歐亞貿(mào)易網(wǎng)

CHANGSHA LANGSHUO TECHNOLOGY CO LTD

其他

  • 經(jīng)營模式:其他
  • 商鋪產(chǎn)品:911條
  • 所在地區(qū):
  • 注冊時間:2025-07-13
  • 最近登錄:2025-07-13
  • 聯(lián)系人:
產(chǎn)品簡介

R-450RoHSdetectorR-450X-rayfluorescencespectrometerbenchtopspectrometerrohselementanalysisinstrument1

詳情介紹

R-450 RoHS detector

R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument
1.1. Instrument specifications

Instrument cavity dimensions439mmX300mmX150mm
The external dimension of the instrument550mmX410mmX320mm
The weight of the instrument45kg

R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument
1.4. Working Conditions:

Working temperature15-30oC
Relative humidity40% ~ 50%
Power sourceAC :220V ±5V

R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument
1.5. Technical performance and Indicators:

1.5.1. Elemental analysis ranges from sulfur (S) to uranium (U);

1.5.2. Element content analysis ranges from 1 PPm to 99.99%;

1.5.3. Measurement time: 100-300 seconds;

1.5.4. The detection limit of harmful elements (limited to Cd/Pb/Cr/Hg/Br) stipulated in the RoHS directive is up to 1PPM;

1.5.5. Energy resolution of 129±5 electron volts;

1.5.6. The temperature adaptation range is 15oC to 30oC;

1.5.7 Power supply: AC 220V±5V; (AC purified and regulated power supply is recommended.)

R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument
1.6. Product features

1.6.1 R-450 is a product designed specifically for RoHS, EN71 and other environmental directives.

1.6.2 Break the traditional linear design of the instrument and adopt the integrated design of streamline body, making the instrument fashionable and generous.

1.6.3 The new SDD detector from the United States is adopted, which is electrically cooled instead of liquid nitrogen. It has small size, accurate data analysis and low maintenance cost.

1.6.4 SES signal processing system independently developed is adopted to effectively improve the sensitivity of measurement and make the measurement more accurate.

1.6.5 One-button automatic test is simpler, more convenient and more user-friendly.

1.6.6 Seven kinds of optical path correction collimation system, according to different samples automatically switch.

1.6.7 Multiple anti-radiation leakage design, the radiation protection level is the Highest of similar products.

1.6.8 Advanced integrated heat dissipation design greatly improves the heat dissipation performance of the whole machine and ensures the operation safety of core components.

1.6.9 Unique movement temperature control technology ensures the safe and reliable operation of X-ray source, effectively prolongs its service life and reduces the operating cost.

1.6.10 Multiple instrument accessories protect the system, and can be monitored through software, so that the instrument work more stable and safer.

1.6.11RoHS special testing software, standard Windows design, friendly interface, easy to operate.

1.6.12 This machine adopts USB2.0 interface to effectively ensure accurate, high-speed and effective data transmission.

R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument
2. The hardware part of the instrument is mainly configured

2.1 SDD electric refrigeration semiconductor Detector: (the latest type of detector)

2.1.1. SDD electric refrigeration semiconductor detector; Resolution: 129±5 electron volts

2.1.2. Amplifier circuit module: detect the characteristic X-ray of the sample; Take the information collected by the probe and enlarge it further.

R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument
2.2 X-ray Excitation Device:

2.2.1. Filament current output MAX: 1mA;

2.2.2. Part of half loss type, 50W, air cooled.

R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument
2.3 High-pressure launcher:

2.3.1. Voltage output MAX: 50KV;

2.3.2. Voltage output MIN: 5KV

2.3.3. Equipped with voltage overload protection

R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument
2.4 Multi-channel Analyzer:

2.4.1. Convert the collected analog signals into digital signals, and provide the processing results to the upper computer software.

2.4.2 Number of tracks MAX: 4096;

2.4.3 Includes signal enhancement processing

R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument
2.5 Optical Path Filter Module

2.5.1 Reduce interference during X-ray path transmission to ensure accurate signal receiving by the detector.

2.5.2 Integrate the collimator with the filter;

R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument
2.6 Collimator Automatic switching Module

2.6.1 Up to 8 choices, calibers are 8 #, 6 #, 4 #, 3 #, 2 #, 1 #, 0.5 #,0.2 #.

2.7 Filter automatic switching module
2.7.1 Free selection and switching of six filters.

2.8 Automatic selection module of working curve

2.9.1 Automatic selection of work curve, abandon manual selection, avoid human error, automatic and intelligent

The interpretation is more perfect, so that the operation is more human, more convenient.

3. Dedicated software JPSPEC-FP

4.1.1 Software Introduction

Specially developed for RoHS detection, data processing, calculation and report the measurement results of the acquired spectral signal.

4.1.2 Function Description
It is specially designed to test the six elements Cd, Pb, Hg, Br, Cr and Cl of the six substances in the EU RoHS Directive, and the measurement time is 100-300 seconds

Simple and intuitive operation interface, easy to use, without professional operation

As shown in the picture below:
?1.Suitable calibration curve can be selected automatically, making the measurement more convenient and accurate.

2.Chinese and English interface automatically switches, and has the function of third-party language customization

3.Automatic calibration instrument.

4.It comes with qualitative analysis of sample material to prevent manual users from choosing wrong curve

5.Print multiple report forms.

6.Multiple spectral images can be displayed simultaneously

7.Unique movement temperature monitoring technology ensures the safe and reliable operation of the X-ray source, effectively prolongs its service life and reduces the use cost.

R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument
4. Sample configuration

Standard samples are used to make working curves

4.1 Sample Chamber

Open large sample cavity

4.2 Standard Sample

Eu standard sample E60K

Sterling silver sample
????R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.1. Instrument specifications Instrument cavity dimensions439mmX300mmX150mm The external dimension of the instrument550mmX410mmX320mm The weight of the instrument45kg  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.4. Working Conditions: Working temperature15-30oC Relative humidity40% ~ 50% Power sourceAC :220V ±5V  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.5. Technical performance and Indicators:  1.5.1. Elemental analysis ranges from sulfur (S) to uranium (U);  1.5.2. Element content analysis ranges from 1 PPm to 99.99%;  1.5.3. Measurement time: 100-300 seconds;  1.5.4. The detection limit of harmful elements (limited to Cd/Pb/Cr/Hg/Br) stipulated in the RoHS directive is up to 1PPM;  1.5.5. Energy resolution of 129±5 electron volts;  1.5.6. The temperature adaptation range is 15oC to 30oC;  1.5.7 Power supply: AC 220V±5V; (AC purified and regulated power supply is recommended.)  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.6. Product features  1.6.1 R-450 is a product designed specifically for RoHS, EN71 and other environmental directives.  1.6.2 Break the traditional linear design of the instrument and adopt the integrated design of streamline body, making the instrument fashionable and generous.  1.6.3 The new SDD detector from the United States is adopted, which is electrically cooled instead of liquid nitrogen. It has small size, accurate data analysis and low maintenance cost.  1.6.4 SES signal processing system independently developed is adopted to effectively improve the sensitivity of measurement and make the measurement more accurate.  1.6.5 One-button automatic test is simpler, more convenient and more user-friendly.  1.6.6 Seven kinds of optical path correction collimation system, according to different samples automatically switch.  1.6.7 Multiple anti-radiation leakage design, the radiation protection level is the Highest of similar products.  1.6.8 Advanced integrated heat dissipation design greatly improves the heat dissipation performance of the whole machine and ensures the operation safety of core components.  1.6.9 Unique movement temperature control technology ensures the safe and reliable operation of X-ray source, effectively prolongs its service life and reduces the operating cost.  1.6.10 Multiple instrument accessories protect the system, and can be monitored through software, so that the instrument work more stable and safer.  1.6.11RoHS special testing software, standard Windows design, friendly interface, easy to operate.  1.6.12 This machine adopts USB2.0 interface to effectively ensure accurate, high-speed and effective data transmission.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2. The hardware part of the instrument is mainly configured  2.1 SDD electric refrigeration semiconductor Detector: (the latest type of detector)  2.1.1. SDD electric refrigeration semiconductor detector; Resolution: 129±5 electron volts  2.1.2. Amplifier circuit module: detect the characteristic X-ray of the sample; Take the information collected by the probe and enlarge it further.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.2 X-ray Excitation Device:  2.2.1. Filament current output MAX: 1mA;  2.2.2. Part of half loss type, 50W, air cooled.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.3 High-pressure launcher:  2.3.1. Voltage output MAX: 50KV;  2.3.2. Voltage output MIN: 5KV  2.3.3. Equipped with voltage overload protection  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.4 Multi-channel Analyzer:  2.4.1. Convert the collected analog signals into digital signals, and provide the processing results to the upper computer software.  2.4.2 Number of tracks MAX: 4096;  2.4.3 Includes signal enhancement processing  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.5 Optical Path Filter Module  2.5.1 Reduce interference during X-ray path transmission to ensure accurate signal receiving by the detector.  2.5.2 Integrate the collimator with the filter;  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.6 Collimator Automatic switching Module 2.6.1 Up to 8 choices, calibers are 8 #, 6 #, 4 #, 3 #, 2 #, 1 #, 0.5 #,0.2 #.  2.7 Filter automatic switching module 2.7.1 Free selection and switching of six filters.  2.8 Automatic selection module of working curve  2.9.1 Automatic selection of work curve, abandon manual selection, avoid human error, automatic and intelligent  The interpretation is more perfect, so that the operation is more human, more convenient.   3. Dedicated software JPSPEC-FP  4.1.1 Software Introduction  Specially developed for RoHS detection, data processing, calculation and report the measurement results of the acquired spectral signal.   4.1.2 Function Description It is specially designed to test the six elements Cd, Pb, Hg, Br, Cr and Cl of the six substances in the EU RoHS Directive, and the measurement time is 100-300 seconds  Simple and intuitive operation interface, easy to use, without professional operation  As shown in the picture below: 1.Suitable calibration curve can be selected automatically, making the measurement more convenient and accurate.  2.Chinese and English interface automatically switches, and has the function of third-party language customization  3.Automatic calibration instrument.  4.It comes with qualitative analysis of sample material to prevent manual users from choosing wrong curve  5.Print multiple report forms.  6.Multiple spectral images can be displayed simultaneously  7.Unique movement temperature monitoring technology ensures the safe and reliable operation of the X-ray source, effectively prolongs its service life and reduces the use cost.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 4. Sample configuration  Standard samples are used to make working curves  4.1 Sample Chamber  Open large sample cavity  4.2 Standard Sample  Eu standard sample E60K  Sterling silver sample R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.1. Instrument specifications Instrument cavity dimensions439mmX300mmX150mm The external dimension of the instrument550mmX410mmX320mm The weight of the instrument45kg  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.4. Working Conditions: Working temperature15-30oC Relative humidity40% ~ 50% Power sourceAC :220V ±5V  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.5. Technical performance and Indicators:  1.5.1. Elemental analysis ranges from sulfur (S) to uranium (U);  1.5.2. Element content analysis ranges from 1 PPm to 99.99%;  1.5.3. Measurement time: 100-300 seconds;  1.5.4. The detection limit of harmful elements (limited to Cd/Pb/Cr/Hg/Br) stipulated in the RoHS directive is up to 1PPM;  1.5.5. Energy resolution of 129±5 electron volts;  1.5.6. The temperature adaptation range is 15oC to 30oC;  1.5.7 Power supply: AC 220V±5V; (AC purified and regulated power supply is recommended.)  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.6. Product features  1.6.1 R-450 is a product designed specifically for RoHS, EN71 and other environmental directives.  1.6.2 Break the traditional linear design of the instrument and adopt the integrated design of streamline body, making the instrument fashionable and generous.  1.6.3 The new SDD detector from the United States is adopted, which is electrically cooled instead of liquid nitrogen. It has small size, accurate data analysis and low maintenance cost.  1.6.4 SES signal processing system independently developed is adopted to effectively improve the sensitivity of measurement and make the measurement more accurate.  1.6.5 One-button automatic test is simpler, more convenient and more user-friendly.  1.6.6 Seven kinds of optical path correction collimation system, according to different samples automatically switch.  1.6.7 Multiple anti-radiation leakage design, the radiation protection level is the Highest of similar products.  1.6.8 Advanced integrated heat dissipation design greatly improves the heat dissipation performance of the whole machine and ensures the operation safety of core components.  1.6.9 Unique movement temperature control technology ensures the safe and reliable operation of X-ray source, effectively prolongs its service life and reduces the operating cost.  1.6.10 Multiple instrument accessories protect the system, and can be monitored through software, so that the instrument work more stable and safer.  1.6.11RoHS special testing software, standard Windows design, friendly interface, easy to operate.  1.6.12 This machine adopts USB2.0 interface to effectively ensure accurate, high-speed and effective data transmission.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2. The hardware part of the instrument is mainly configured  2.1 SDD electric refrigeration semiconductor Detector: (the latest type of detector)  2.1.1. SDD electric refrigeration semiconductor detector; Resolution: 129±5 electron volts  2.1.2. Amplifier circuit module: detect the characteristic X-ray of the sample; Take the information collected by the probe and enlarge it further.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.2 X-ray Excitation Device:  2.2.1. Filament current output MAX: 1mA;  2.2.2. Part of half loss type, 50W, air cooled.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.3 High-pressure launcher:  2.3.1. Voltage output MAX: 50KV;  2.3.2. Voltage output MIN: 5KV  2.3.3. Equipped with voltage overload protection  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.4 Multi-channel Analyzer:  2.4.1. Convert the collected analog signals into digital signals, and provide the processing results to the upper computer software.  2.4.2 Number of tracks MAX: 4096;  2.4.3 Includes signal enhancement processing  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.5 Optical Path Filter Module  2.5.1 Reduce interference during X-ray path transmission to ensure accurate signal receiving by the detector.  2.5.2 Integrate the collimator with the filter;  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.6 Collimator Automatic switching Module 2.6.1 Up to 8 choices, calibers are 8 #, 6 #, 4 #, 3 #, 2 #, 1 #, 0.5 #,0.2 #.  2.7 Filter automatic switching module 2.7.1 Free selection and switching of six filters.  2.8 Automatic selection module of working curve  2.9.1 Automatic selection of work curve, abandon manual selection, avoid human error, automatic and intelligent  The interpretation is more perfect, so that the operation is more human, more convenient.   3. Dedicated software JPSPEC-FP  4.1.1 Software Introduction  Specially developed for RoHS detection, data processing, calculation and report the measurement results of the acquired spectral signal.   4.1.2 Function Description It is specially designed to test the six elements Cd, Pb, Hg, Br, Cr and Cl of the six substances in the EU RoHS Directive, and the measurement time is 100-300 seconds  Simple and intuitive operation interface, easy to use, without professional operation  As shown in the picture below: 1.Suitable calibration curve can be selected automatically, making the measurement more convenient and accurate.  2.Chinese and English interface automatically switches, and has the function of third-party language customization  3.Automatic calibration instrument.  4.It comes with qualitative analysis of sample material to prevent manual users from choosing wrong curve  5.Print multiple report forms.  6.Multiple spectral images can be displayed simultaneously  7.Unique movement temperature monitoring technology ensures the safe and reliable operation of the X-ray source, effectively prolongs its service life and reduces the use cost.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 4. Sample configuration  Standard samples are used to make working curves  4.1 Sample Chamber  Open large sample cavity  4.2 Standard Sample  Eu standard sample E60K  Sterling silver sample R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.1. Instrument specifications Instrument cavity dimensions439mmX300mmX150mm The external dimension of the instrument550mmX410mmX320mm The weight of the instrument45kg  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.4. Working Conditions: Working temperature15-30oC Relative humidity40% ~ 50% Power sourceAC :220V ±5V  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.5. Technical performance and Indicators:  1.5.1. Elemental analysis ranges from sulfur (S) to uranium (U);  1.5.2. Element content analysis ranges from 1 PPm to 99.99%;  1.5.3. Measurement time: 100-300 seconds;  1.5.4. The detection limit of harmful elements (limited to Cd/Pb/Cr/Hg/Br) stipulated in the RoHS directive is up to 1PPM;  1.5.5. Energy resolution of 129±5 electron volts;  1.5.6. The temperature adaptation range is 15oC to 30oC;  1.5.7 Power supply: AC 220V±5V; (AC purified and regulated power supply is recommended.)  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 1.6. Product features  1.6.1 R-450 is a product designed specifically for RoHS, EN71 and other environmental directives.  1.6.2 Break the traditional linear design of the instrument and adopt the integrated design of streamline body, making the instrument fashionable and generous.  1.6.3 The new SDD detector from the United States is adopted, which is electrically cooled instead of liquid nitrogen. It has small size, accurate data analysis and low maintenance cost.  1.6.4 SES signal processing system independently developed is adopted to effectively improve the sensitivity of measurement and make the measurement more accurate.  1.6.5 One-button automatic test is simpler, more convenient and more user-friendly.  1.6.6 Seven kinds of optical path correction collimation system, according to different samples automatically switch.  1.6.7 Multiple anti-radiation leakage design, the radiation protection level is the Highest of similar products.  1.6.8 Advanced integrated heat dissipation design greatly improves the heat dissipation performance of the whole machine and ensures the operation safety of core components.  1.6.9 Unique movement temperature control technology ensures the safe and reliable operation of X-ray source, effectively prolongs its service life and reduces the operating cost.  1.6.10 Multiple instrument accessories protect the system, and can be monitored through software, so that the instrument work more stable and safer.  1.6.11RoHS special testing software, standard Windows design, friendly interface, easy to operate.  1.6.12 This machine adopts USB2.0 interface to effectively ensure accurate, high-speed and effective data transmission.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2. The hardware part of the instrument is mainly configured  2.1 SDD electric refrigeration semiconductor Detector: (the latest type of detector)  2.1.1. SDD electric refrigeration semiconductor detector; Resolution: 129±5 electron volts  2.1.2. Amplifier circuit module: detect the characteristic X-ray of the sample; Take the information collected by the probe and enlarge it further.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.2 X-ray Excitation Device:  2.2.1. Filament current output MAX: 1mA;  2.2.2. Part of half loss type, 50W, air cooled.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.3 High-pressure launcher:  2.3.1. Voltage output MAX: 50KV;  2.3.2. Voltage output MIN: 5KV  2.3.3. Equipped with voltage overload protection  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.4 Multi-channel Analyzer:  2.4.1. Convert the collected analog signals into digital signals, and provide the processing results to the upper computer software.  2.4.2 Number of tracks MAX: 4096;  2.4.3 Includes signal enhancement processing  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.5 Optical Path Filter Module  2.5.1 Reduce interference during X-ray path transmission to ensure accurate signal receiving by the detector.  2.5.2 Integrate the collimator with the filter;  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 2.6 Collimator Automatic switching Module 2.6.1 Up to 8 choices, calibers are 8 #, 6 #, 4 #, 3 #, 2 #, 1 #, 0.5 #,0.2 #.  2.7 Filter automatic switching module 2.7.1 Free selection and switching of six filters.  2.8 Automatic selection module of working curve  2.9.1 Automatic selection of work curve, abandon manual selection, avoid human error, automatic and intelligent  The interpretation is more perfect, so that the operation is more human, more convenient.   3. Dedicated software JPSPEC-FP  4.1.1 Software Introduction  Specially developed for RoHS detection, data processing, calculation and report the measurement results of the acquired spectral signal.   4.1.2 Function Description It is specially designed to test the six elements Cd, Pb, Hg, Br, Cr and Cl of the six substances in the EU RoHS Directive, and the measurement time is 100-300 seconds  Simple and intuitive operation interface, easy to use, without professional operation  As shown in the picture below: 1.Suitable calibration curve can be selected automatically, making the measurement more convenient and accurate.  2.Chinese and English interface automatically switches, and has the function of third-party language customization  3.Automatic calibration instrument.  4.It comes with qualitative analysis of sample material to prevent manual users from choosing wrong curve  5.Print multiple report forms.  6.Multiple spectral images can be displayed simultaneously  7.Unique movement temperature monitoring technology ensures the safe and reliable operation of the X-ray source, effectively prolongs its service life and reduces the use cost.  R-450 X-ray fluorescence spectrometer benchtop spectrometer rohs element analysis instrument 4. Sample configuration  Standard samples are used to make working curves  4.1 Sample Chamber  Open large sample cavity  4.2 Standard Sample  Eu standard sample E60K  Sterling silver sample

上一篇: Q9600 Six Channel Fluorescence PCR D
下一篇: R-350 RoHS detector
同類優(yōu)質(zhì)產(chǎn)品

在線詢價

X

已經(jīng)是會員?點擊這里 [登錄] 直接獲取聯(lián)系方式

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
安陆市| 定陶县| 台安县| 贵阳市| 延边| 沅陵县| 汾阳市| 东方市| 谢通门县| 景德镇市| 东兴市| 驻马店市| 华安县| 铜川市| 白玉县| 东城区| 大丰市| 广昌县| 孝义市| 收藏| 买车| 泸水县| 通城县| 仪征市| 师宗县| 江安县| 泰州市| 灵丘县| 陆丰市| 准格尔旗| 三原县| 太原市| 偃师市| 西安市| 承德县| 峡江县| 海晏县| 太原市| 伊春市| 通许县| 通城县|